Vacuum feeder operation precautions and cleaning instructions
Operation Precautions 1. Before using the equipment, check whether the air source is clean, otherwise it will block the solenoid valve, cylinder, etc., making the equipment unable to operate normally. The air source should also meet the operating pressure requirement: 0.4-0.6 MPa.. 2. Before using the equipment, check whether the connection of each air pipe is firm, otherwise, when the air pipe with compressed air falls off, it will swing quickly to prevent injury. If this happens, the main air source should be closed immediately. 3. Before using the equipment, check whether the connection of each component is tight; whether the feeder and the bracket are firm.
Operation Precautions
1. Before using the equipment, check whether the air source is clean, otherwise it will block the solenoid valve, cylinder, etc., making the equipment unable to operate normally. The air source should also meet the operating pressure requirement: 0.4-0.6 MPa..
2. Before using the equipment, check whether the connection of each air pipe is firm, otherwise, when the air pipe with compressed air falls off, it will swing quickly to prevent injury. If this happens, the main air source should be closed immediately.
3. Before using the equipment, check whether the connection of each component is tight; whether the feeder and the bracket are firm.
4. Adjust the feeding time and discharging time. Set the feeding time to 10-30 seconds and the discharging time to 2-6 seconds by touching the increase and decrease buttons.
5. During the material conveying process, large static electricity will be generated due to friction. In order to eliminate static electricity, reliable grounding of the equipment shell should be considered.
5. liquid circulation type vacuum pump/compressor operation problems, should immediately notify the maintenance personnel for maintenance.
Cleaning
In the production process, due to the replacement of different varieties or batch numbers, the vacuum feeder needs to be cleaned frequently. The pneumatic vacuum feeder has fully considered the user's requirements, and only needs to be cleaned:
1. Loosen the quick-opening clamp and remove the cover of the hopper. The air bag and the cover are connected as a whole, because it is blocked by the filter, the piece does not need to be cleaned with water.
2. Remove the filter assembly, blow off the powder on the filter rod with compressed air, and then flush it repeatedly with hot water. After flushing, flush the accumulated water in the fine holes of the filter with compressed air. At this time, blow back the filter rod smoothly. If you hold your breath, it indicates that there is still accumulated water in the filter pipe wall. You need to continue to blow it with compressed air, and then cool or dry it.
3. Loosen the quick-opening clamp, remove each pipe section of the vacuum hopper, and clean it with water.
4, the specific can be determined according to the situation of the work site.